Evaluating parts after UV Post-cure

  1. Allow the part to cool to ambient temperature before removing from the UV chamber to avoid dimensional inconsistencies.

  2. After parts have completed the recommended cure time and some surfaces are found to still be tacky, follow the steps below to remove any remaining tackiness.

  • Submerge part in clean bath of IPA for 10 minutes

  • Remove part from IPA bath and dry with compressed air