Printer Advance Preparation Checklist

Unless governed by prior arrangement, 3D Systems is not responsible for loading the client software on the user's workstation(s).  BEFORE THE PRINTER ARRIVES, ensure that your workstation is capable of supporting the requirements of both the client software and communication with the machine via your network. 

Review this list with a network administrator, IT department, facilities manager or other responsible persons within your organization. Complete and place a check mark next to each item. Once everything is complete, photocopy this page, and fax it to the number checked or provided on the bottom of the inside back cover of this document. If no number is provided or relevant, then fax to +1 970-257-4601 (U.S.A). 

Please complete the following (if making a copy to fill in, please print): 

 

Company Name: _______________________________________________________________________ 

Contact (Print full name): ______________________________________________________________ 

Date faxed: ____________________________________________________________________________ 

Telephone (with area code): ___________________________________________________________ 

Email: __________________________________________________________________________________ 
 

Please place a check in each box once that item is complete. Check Box
Final installation site selected.  The intended physical location for each ProJet® Professional Printing System(s) should be selected in advance, and checked for adherence to the guidelines set out in this guide.  
If required by the shipper, a method of removing the crate from the shipper’s truck has been arranged (forklift is required) and is available to transfer the crate(s) to the de-crating location.  
NETWORK CONNECTION IS INSTALLED. An RJ45 (UTP, female connection jack) Ethernet network connection for EACH printer that is to be installed at the delivery site must be installed, tested and functioning.  
Operating system and workstation configurations are compatible and meet the minimum requirements as stated in the section, “Client Workstation Requirements”.  
TCP/IP is installed and enabled.  
Static IP address(es) has been allocated for each printer ordered. A permanent IP address on the network is assigned (presumably by a Network Administrator) to each printer that is to be connected to the network. 
Enter IP address: ___________________________________________________
 
Test each IP address by pinging it, or by temporarily connecting a network resource (such as a workstation or a Printer) and “pinging” from another workstation on the network.  
Dedicated line, with a surge-and-spike-protected electrical power circuit for each printer, meeting one of the following specifications.  Place check mark beside the appropriate specification:
____ 115 VAC, 50/60 Hz (dedicated 20 amp breaker)
____ 230 VAC 50/60 Hz (dedicated 15 amp breaker)
 

Optional uninterrupted power supply (customer purchased) with a minimum 5kVA supplying 120V. The customer is responsible for correct power to the UPS and from the UPS to operate the ProJet 5600 at correct voltages and current requirements.  90-120VAC @ 20amps maximum. Place a check mark to either Yes or No :

____ Yes
____ No

 

Before the printer is installed into this facility, we acknowledge that the installation site complies with the specifications stated in the 
ProJet™ Facility Requirements Guide. Once the printer is installed, we agree not to alter any requirements without consulting with 3D 
Systems' Customer Service Representative. If alteration are made without consulting 3D Systems, it may void the system's warranty. 

 

Customer Signature: _________________________________________________________ Date: _______________