Operating Environment

Locate the printer in a convenient location meeting the requirements specified in this document. The printer is designed for indoor use only. To ensure optimum performance, it is important that the printer must be installed in a clean, dry, air-conditioned room. Avoid placing the printer in any environment with airborne contaminants, including cigarette smoke, fumes, and mechanical particulates that can adversely affect the long term functioning of this equipment.  

Air Conditioning
A number of the ProJet® MJP 5600 System's internal electronic components as well as the part material, are sensitive both to ambient temperature and, to some extent, humidity. In addition, the build process itself can be temperature-sensitive within certain limits. The operating temperature range should be between 18-28°C (64-82°F); optimally approximately 21-24°C (70-75°F). 

Humidity 
Humidity should be maintained at 30-70% relative humidity. 

Lighting 
The printer is equipped with its own internal light build chamber, and back lit operating panel control with display. 

Vibration and Shock 
The printer consists of many precision mechanical and sensing systems that are sensitive to vibration during the build process. To maximize the quality and accuracy of the build, it is required that the unit not be near heavy machinery or any source causing high vibration or shock (i.e. exterior walls near train tracks or airports). 

Note.png

NOTE: The printer MUST be placed on a vibration free concrete floor. Do not install on any other floor covering such as vinyl, tile, carpeting, etc.. Doing so WILL affect machine performance. 

Elevation 
Elevation up to 2000 meters ( 6561 feet).