An extended material changeover is required when moving from M2E-BK70 to any other VisiJet material. The extended changeover wizard will be automatically initiated by the printer and requires no special knowledge from the user. The extended changeover requires a 12 hour deep clean; this is best done overnight. The extended material changeover takes approximately 500g per bottle of cleaner material, so the bottles must be at least 50% full.
- Ensure printer is in Ready state. Select Tools > Material Change Wizard from the UI.
- Select
to start the Material Change Wizard.
- Verify you have the required material on hand to start the Extended Material Changeover procedure and select "Continue".
![]() |
- "The Material Change Wizard will display the progress steps"
![]() |
- When prompted, remove the current part material cartridges and close the MDM drawer, and select "Continue".
![]() |
- Once the printer has flushed out the exisiting part material from the system you will be prompted to insert two MCO Cleaner 2500 cartridges and close the MDM drawer. Select "Continue".
![]() |
NOTE: This step can take 30-45 minutes to complete. |
![]() |
NOTE: If the cartridges are cold the process will take an additional 30 minutes to allow material to warm before continuing. |
- The MCO Cleaner material flushes the rest of the part material out. This can take 30-45 minutes.
![]() |
- When prompted, remove the MCO Cleaner cartridges from the MDM and close the drawer. Select "Continue". The printer will proceed to flush the Cleaner material from the system.
![]() |
- After the printer flushes the Cleaner material, when prompted re-insert the MCO Cleaner cartridges and the printer will proceed to step 3, Deep Clean.
- Press
to cancel Deep Clean and exit Extended Material Changeover.
![]() |
- When prompted, remove the MCO Cleaner cartridges from the MDM and close the drawer. Select "Continue". The printer will proceed to flush the Cleaner material from the system.
![]() |
- When prompted, install the original part material in the MDM prior to starting Extended MCO. Select "Continue". The printer will proceed to fill the part material in the system.
![]() |
- If the printer completes Deep Clean, then when prompted, remove the MCO Cleaner cartridges from the MDM and close the drawer. Select "Continue". The printer will proceed to flush the Cleaner material from the system.
![]() |
- After the printer flushes the Cleaner material, when prompted insert the cleaner cartridges. The printer will proceed to flush the Cleaner material from the system.
![]() |
- When prompted, remove the MCO Cleaner cartridges from the MDM and close the drawer. Select "Continue". The printer will proceed to flush the Cleaner material from the system.
![]() |
- When the Cleaner material has been flushed from the printer, when prompted, insert the new part material cartridges into the MDM. Select "Continue".
![]() |
NOTE: If the cartridges are cold the process will take an additional 30 minutes to allow material to warm before continuing. |
![]() |
- This step can take 30-60 minutes to complete loading the new material into the system.
![]() |
- Once the Material Changeover Process is complete a confirmation screen will appear. It is recommended to clean and inspect the planarizer blade and ducts once the Material Changeover is completed.
![]() |