Printer Power requirements:
90-100V, 7.5A
110-120V, 5.5A
208-240V, 4.0A

Core Recycling Unit Power requirements:
Unit in operation

100 - 120V~, 50-60 Hz, 1.4 Amps.

230V~, 50-60 Hz, 0.7 Amps.

Unit in Sleep Mode - 0.5 W

100 - 120V~, 50-60 Hz, 0.004 Amps.

230V~, 50-60 Hz, 0.002 Amps.

Printer dimensions

29 x 31 x 55 inches

(74 x 79 x 140 cm)

Core Recycling Unit dimensions

With glass closed: 23” wide x 23” deep x 28” high (59cm wide x 59cm deep x 72cm high).

With glass open: 23” wide x 23” deep x 49” high (59cm wide x 59cm deep x 125cm high).

Printer weight
365 lbs (165 kg)

Core Recycling Unit weight
51 pounds (23kg)

Ventilation
Printer: None
Core Recycling Unit: None

Post Processing: Visit 3DS Central at https://3dscentral.3dsystems.com/

Operating Conditions
Ambient Temperatures:

  • Maximum Temp. Range: 55-80° F (12.7-26.6° C)
  • Recommended Temp. Range: 55-75° F (12.7-23.8°C)

Ambient Relative Humidity

  • Maximum RH Range: 15-65%, non-condensing
  • Recommended RH Range: 20-55%, non-condensing
  • May experience sub-optimal performance at extremes.

Noise Levels

  • During Printing = 57dB
  • Emptying Overflow = 66dB