Clean Tension System

Frequency: Monthly

To clean the tension latches on the left and right sides of the chassis:

WEAR 100% nitrile gloves throughout this procedure.

 

  1. Untension the resin tray and carefully remove it. Place it in the resin-tray garage with the lid on.

print-tray-garage-v2.jpg

release-manual-tension-arm-v9.gif
  1. Remove both vanity covers from the printer chassis. Clean the vanity covers with a nonabrasive cloth and 90% alcohol solution.
remove-vanity-covers.jpg
  1. Pour 90% alcohol solution on a nonabrasive cloth. Clean both latches and inspect them for any signs of damage. If there is damage, contact your reseller.
clean-tension-latches-1.jpg
  1. Clean the top and bottom of the tension arm itself with 90% alcohol solution. Inspect the tension arm for any signs of damage. If there is damage, contact your reseller.
  2. Reinstall the vanity covers over the chassis.
top-and-bottom-tension-arm.jpg

Cleaning of the tension system is now complete.